Vortice Punto MFO 100/4" wall axial fan (11145)
The Vortice Punto MFO 100/4 axial fan is a wall-mounted extractor fan with a nominal diameter of 100 mm. We recommend it for small and medium-sized residential and commercial premises where the air can be discharged outside directly or through a short duct. In free air it moves up to 85 cubic metres of air per hour, its absorbed power is 15 W and its sound pressure measured at 3 m is 33.1 dB(A).
Thanks to its IPX4 rating, meaning it is protected against splashing water, it is also suitable for ventilating bathrooms, WCs and other utility rooms. A non-return valve in the exhaust sleeve prevents air and odours from flowing back when the fan is switched off. Our expert staff will help you with sizing and choosing accessories.

Vortice Punto MFO 100/4: quiet wall axial fan
The Vortice Punto MFO 100/4 axial fan is a wall-mounted extractor fan with a nominal diameter of 100 mm. We recommend it for small and medium-sized residential and commercial premises where the air can be discharged outside directly or through a short duct. It can also be installed in bathrooms and WCs.
In free air it moves up to 85 cubic metres of air per hour, its absorbed power is 15 W and its sound pressure measured at 3 m is 33.1 dB(A). The manufacturer's name for the series is Punto Four.
If you want it to start together with the light and keep running afterwards, we recommend the Vortice Punto MFO 100/4 T variant with an adjustable run-on timer, which you will find on its own page.
You will find more bathroom and WC fans on the category page. Axial fans for short ducts can also be found among the axial fans for duct lengths under 1.5 m.
Which variant do you need?
Three sizes, each without and with a timer; highlighted: the variant you are viewing.
| Variant | Timer | Air flow in free air | Absorbed power | Sound pressure at 3 m | Code |
|---|---|---|---|---|---|
| MFO 90/3.5 | none | 65 m³/h | 14 W | 29.6 dB(A) | 11143 |
| MFO 90/3.5 T | 3-20 min, adjustable | 65 m³/h | 14 W | 29.6 dB(A) | 11144 |
| You are viewing this: MFO 100/4 | none | 85 m³/h | 15 W | 33.1 dB(A) | 11145 |
| MFO 100/4 T | 3-20 min, adjustable | 85 m³/h | 15 W | 33.1 dB(A) | 11146 |
| MFO 120/5 | none | 175 m³/h | 20 W | 39.1 dB(A) | 11147 |
| MFO 120/5 T | 3-20 min, adjustable | 175 m³/h | 20 W | 39.1 dB(A) | 11148 |
The size is the nominal diameter of the fan in millimetres: 90, 100 or 120 mm. The T variants have a run-on timer; all their other data are the same as those of the basic model of the same size. The table shows the air flow of the fan in free air, which the resistance of the duct reduces.
Why choose this fan?

Flat front panel, hidden wall opening
The flat front panel hides the wall opening, so the installed fan is barely noticeable. The front panel is made of white, shock-proof, UV-resistant ABS plastic. It is held by a single screw, so it is easy to remove for cleaning.

Non-return valve in the exhaust sleeve
A non-return valve in the exhaust sleeve prevents air and odours from flowing back when the fan is switched off. The airfoil-shaped blades of the impeller combine high performance with low noise. The motor is a shaded pole motor with thermal protection and self-lubricating sleeve bearings.

Simple switching, adjustable speed
The basic model is started and stopped with the wall switch. You can adjust its speed with the Vortice C 1.5 electronic speed controller, which is designed for the basic models. Please ask our staff about obtaining the controller.

For bathrooms and WCs
Thanks to its IPX4 rating, meaning it is protected against splashing water, it is also suitable for ventilating bathrooms, WCs and other utility rooms. It is protection class II, so no earthing is required. The extracted air may be at most 50 °C.

Short sleeve, small installation depth
The exhaust sleeve is short, so a 90° bend can be connected directly behind it. The air must be discharged directly outside or through a duct no longer than 400 mm, because performance drops in longer ducts or in ducts with high resistance.

For walls and ceilings
It can be installed on walls, ceilings and false ceilings. On a ceiling, install it only with the gasket of the separately available Vortice SF kit, as this is the only way to keep the IPX4 rating. The SF 90-100 kit (22162) fits the 90 and 100 sizes, and the SF 120 kit (22163) fits the 120 size.
Technical data
| Feature | Value |
|---|---|
| Type | Vortice Punto MFO 100/4, code 11145 |
| Nominal diameter | 100 mm |
| Air flow in free air | 85 m³/h (24 l/s) |
| Maximum pressure | 29 Pa (3.0 mmH2O) |
| Speed | 2,400 rpm |
| Absorbed power | 15 W |
| Absorbed current | 0.09 A |
| Sound pressure | 33.1 dB(A), measured at 3 m |
| Sound power (LWA) | 54 dB(A) |
| Timer | none |
| Weight | 0.555 kg |
| Supply voltage | 220-240 V, 50 Hz, single-phase |
| Motor | shaded pole, with thermal protection and self-lubricating sleeve bearings |
| Impeller | axial, with airfoil-shaped blades |
| Front panel | white, shock-proof, UV-resistant ABS plastic |
| Non-return valve | in the exhaust sleeve |
| IP rating | IPX4 |
| Protection class | II (earthing not required) |
| Ambient temperature in continuous operation | max. 50 °C |
| Mounting | wall, ceiling (with SF kit), false ceiling |
The data according to the ErP Regulation (1254/2014/EU) are in the ErP table of the English catalogue pages. The manufacturer is Vortice of Italy.
Dimensions
Letters as in the manufacturer drawing, dimensions in millimetres.

- A: width of the front panel.
- B: how far the fan protrudes from the wall surface, from the back of the base plate to the front of the front panel.
- C: total depth from the end of the exhaust sleeve to the front of the front panel.
- ØD: outside diameter of the exhaust sleeve.
| Size | A | B | C | ØD | Wall opening Ø | Hole spacing |
|---|---|---|---|---|---|---|
| MFO 90/3.5 | 158 | 37 | 97 | 92.4 | 95 | 133 |
| MFO 100/4 | 158 | 37 | 97 | 98.4 | 102 | 133 |
| MFO 120/5 | 178 | 42.3 | 114 | 118.9 | 122 | 153 |
The front panel of the MFO 100/4 is 158 mm wide and the outside diameter of the exhaust sleeve is 98.4 mm. The wall needs an opening of 102 mm diameter, and the four fixing holes are at the corners of a 133 mm square.
Performance curve
Pressure and absorbed power as a function of air flow.

The thin line shows the pressure of the fan (Pa, left scale) and the thick line its absorbed power (W, right scale) as a function of air flow (m³/h, bottom scale). The curve applies to both variants of the MFO 100/4.
Installation and connection
Positioning, wall opening, mounting and electrical connection.
Installation

- The fan must be installed more than 2.3 m above the floor.
- If the fan is installed where the wall meets the tiling, a spacer must compensate for the difference in level.
- The impeller must not be reachable by hand from the outlet side; if it is, a protective grille must be fitted.
- Enough fresh air must be able to enter the room.
- If an open-flued gas appliance or other combustion appliance operates in the same room, the air supply must be sufficient for all of them, and flue gas must be prevented from flowing back into the room.
Wall opening and fixing
The diameter of the wall opening and the spacing of the four fixing holes are shown in the figures and in the dimension table.


Installation steps

- Remove the front panel: undo the fixing screw at the bottom and tilt the panel forward.
- Make the wall opening according to the dimension table.
- Mark the four holes, drill them with a 6 mm drill bit and insert the wall plugs.
- Feed in the power cable and screw the fan to the wall.
- Connect it according to the wiring diagram; the stripped end of the wire must be no longer than 8 mm.
- Refit the front panel and switch the power back on.
Electrical connection

- Installation and connection may only be carried out by a qualified electrician.
- It must be connected to the mains through an omnipolar switch with a contact opening of at least 3 mm, which fully disconnects the circuit under overvoltage category III conditions.
- The supply voltage must match the value on the fan's rating plate.
- The basic model is connected to terminals N1 and L2; the switch must be two-pole.
Maintenance
Cleaning with the power disconnected.

- Before cleaning, switch off the main switch or the circuit breaker.
- Dust the front panel and the openings with a soft brush.
- Do not immerse the front panel in water.
- If the fan has to be dismantled for cleaning, leave this to a qualified technician.
- If the fan has been dropped or has suffered a heavy impact, have it checked by a qualified technician before use.
What is it not suitable for?
Limits of use.
- It must not be installed outdoors and must not be exposed to rain or sun.
- The air conveyed must not contain grease, soot, chemicals, or corrosive, explosive or flammable substances.
- It must not be used near flammable vapours such as alcohol, insecticides or petrol.
- It is not designed to activate water heaters or heating appliances, and it must not discharge into hot-air flues.
- Do not cover the inlet and outlet openings.
- We do not recommend it for continuous operation, as this shortens its service life.
Manufacturer's documents
The English chapter of the instruction manual contains the safety instructions, its figures show installation, wiring and cleaning, and the English catalogue pages give the technical data, performance curves and accessories.
Accessories for installation
Gravity shutters, rain guard grilles, PVC pipes and aluminium tape from our online shop; our staff will help you choose the right size.

Buy from one of Hungary's most trusted ventilation specialists
Ventilátorház is located at Királyhágó utca 30 in Budapest's XVIII. district. We are a multi-award-winning company with decades of experience. Our expert staff will help you with sizing and choosing accessories. Call them on +36-70-369-9944.
Frequently asked questions
The MFO 100/4 needs a wall opening of 102 mm diameter. The outside diameter of the sleeve is 98.4 mm; the other dimensions are given in the dimension table.
To a duct of up to 400 mm, or it can discharge directly outside. Our staff will help you choose.
Yes, but only with the gasket of the Vortice SF ceiling kit, which is not included.
Yes, the Vortice Punto MFO 100/4 T starts together with the light and then keeps running for 3-20 minutes.
Yes, with the Vortice C 1.5 electronic speed controller.
No, it is double insulated.
We do not recommend it, because continuous operation shortens its service life. The other limits of use are listed in the What is it not suitable for? section.
In free air, measured at 3 m, its sound pressure is 33.1 dB(A).
Yes, for example the Vortice MICRO 100 centrifugal fan.