Nemes Ventilátorház

Kérdése van? +36-70-369-9944

Categories
Nemes Ventilátorház

Kérdése van? +36-70-369-9944

  • Categories
    • Bathroom and toilet extractor fans
    • Window Fans
    • Cooker hoods
    • Industrial ventilation accessories
    • Industrial ventilation
    • Commercial kitchen extract fans
    • In-line duct fans
    • Centrifugal fans (low pressure)
    • Heat Recovery Systems
    • PVC heat recovery distribution boxes and valve plenums
    • Metal heat recovery distribution boxes and valve plenums
    • Heat recovery system installation materials
    • Metal fittings
    • Metal ducts (rigid and flexible)
    • Duct heaters
    • Silencers
    • Air inlets
    • Air valves
    • Instrument fans
    • Butterfly dampers
    • Rigid round PVC ducts and fittings
    • Rigid rectangular PVC ducts and fittings
    • Flexible PVC ducts
    • Grilles and louvres
    • Fixing and suspension clamps
    • Controllers and electronics
    • Installation accessories
    • Insulated rigid ducts and fittings
    • Insulation materials
    • Access doors
    • Filter boxes and filter media
    • Roof terminals and roof cowls
    • Fire protection products
    • Fan accessories
    • Backdraught shutters
    • Fan filters
Vortice Punto MFO 100/4 T axial fan with run-on timer (11146)
Vortice Punto MFO 100/4 T axial fan with run-on timer (11146)
86 €
  1. Bathroom and toilet extractor fans
  1. Bathroom and toilet extractor fans

Vortice Punto MFO 100/4 T axial fan with run-on timer (11146)

Vortice Punto MFO 100/4 T axial fan with run-on timer (11146)
Vortice Punto MFO 100/4 T axial fan with run-on timer (11146)
Vortice Punto MFO 100/4 T axial fan with run-on timer (11146)
Vortice Punto MFO 100/4 T axial fan with run-on timer (11146)
Vortice Punto MFO 100/4 T axial fan with run-on timer (11146)
Vortice Punto MFO 100/4 T axial fan with run-on timer (11146)
Vortice Punto MFO 100/4 T axial fan with run-on timer (11146)
Vortice Punto MFO 100/4 T axial fan with run-on timer (11146)
Vortice Punto MFO 100/4 T axial fan with run-on timer (11146)
Vortice Punto MFO 100/4 T axial fan with run-on timer (11146)
Vortice Punto MFO 100/4 T axial fan with run-on timer (11146)
Vortice Punto MFO 100/4 T axial fan with run-on timer (11146)
Vortice Punto MFO 100/4 T axial fan with run-on timer (11146)
Vortice Punto MFO 100/4 T axial fan with run-on timer (11146)
Vortice Punto MFO 100/4 T axial fan with run-on timer (11146)
Vortice Punto MFO 100/4 T axial fan with run-on timer (11146)
Vortice Punto MFO 100/4 T axial fan with run-on timer (11146)
Vortice Punto MFO 100/4 T axial fan with run-on timer (11146)
Vortice Punto MFO 100/4 T axial fan with run-on timer (11146)
Vortice Punto MFO 100/4 T axial fan with run-on timer (11146)
86 €

The Vortice Punto MFO 100/4 T axial fan comes with an adjustable timer and has a nominal diameter of 100 mm. We recommend it for small and medium-sized residential and commercial premises where the air can be discharged outside directly or through a short duct. In free air it moves up to 85 cubic metres of air per hour, its absorbed power is 15 W and its sound pressure measured at 3 m is 33.1 dB(A).

Thanks to its IPX4 rating, meaning it is protected against splashing water, it is also suitable for ventilating bathrooms, WCs and other utility rooms. It switches on automatically a few seconds after the light is switched on and, after the light is switched off, keeps running for the set time of 3-20 minutes. Our expert staff will help you with sizing and choosing accessories.

Diameter Diameter:
90
100
120
Convenience Features Convenience Features:
Standard
Run-on timer
Max. Airflow Max. Airflow:
85 m3/h
100 napos pénzvisszafizetési garancia
100 napos visszafizetési garancia
Tudjon meg többet!
Ingyenes légtechnikai tanácsadás
Országos kiszállítás
akár másnapra
Mindössze 2500 forintért
Data
Type of Airflow:
Axial
Availability:
Available to order
Diameter:
100
Convenience Features:
Run-on timer
Mounting Method:
Wall and ceiling
Noise Level:
Quiet
Max. Airflow:
85 m3/h
Manufacturer:
Vortice
Bearing Type:
Sleeve bearing
Speed Levels:
Single-speed
Louvre:
Backdraught shutter
Pipe Insertable:
No
Protection:
IPX4
Colour:
White
Material:
Plastic housing
Max. pressure:
29 Pa
Voltage:
230
Number of phases:
1
Max. current consumption:
0.09 A
Run-on ventilation:
Yes
Motor type:
Single-phase
Power consumption:
15 W
Depth:
9.7 cm
Rated speed (rpm):
2 400
Air temperature range (°C):
max. +50
Manufacturer's part number:
11146
Product family:
Vortice Punto Four
Width (mm):
158
Height (mm):
158
Sound pressure at 3 m (dB(A)):
33.1
Sound power (LWA, dB):
54
Weight:
575 g/db
Professzionális bemutatóterem
Professzionális bemutatóteremPróbálja ki termékeinket Budapesten, a Királyhágó utca 30. alatt
Ingyenes szaktanácsadás
Ingyenes szaktanácsadásTapasztalt és segítőkész szakembereink várják hívását
Megbízható kereskedő
Megbízható kereskedő32 év tapasztalatával az ország egyik legnagyobb forgalmazója
Díjnyertes vállalkozás
Díjnyertes vállalkozásDíjainkat és kiemelkedő értékeléseinket tisztességes üzletvitelünk miatt kaptuk
Details
Vortice Punto Four MFO wall axial fan in white with a flat front panel, the exhaust sleeve at the side (manufacturer photo)

Vortice Punto MFO 100/4 T: wall axial fan with run-on timer

The Vortice Punto MFO 100/4 T axial fan comes with an adjustable timer and has a nominal diameter of 100 mm. We recommend it for small and medium-sized residential and commercial premises where the air can be discharged outside directly or through a short duct. It can also be installed in bathrooms and WCs.

In free air it moves up to 85 cubic metres of air per hour, its absorbed power is 15 W and its sound pressure measured at 3 m is 33.1 dB(A). The manufacturer's name for the series is Punto Four.

For operation by switch without a timer, we recommend the Vortice Punto MFO 100/4 basic model, which you will find on its own page.

You will find more bathroom and WC fans on the category page. Axial fans for short ducts can also be found among the axial fans for duct lengths under 1.5 m.

Which variant do you need?

Three sizes, each without and with a timer; highlighted: the variant you are viewing.

VariantTimerAir flow in free airAbsorbed powerSound pressure at 3 mCode
MFO 90/3.5none65 m³/h14 W29.6 dB(A)11143
MFO 90/3.5 T3-20 min, adjustable65 m³/h14 W29.6 dB(A)11144
MFO 100/4none85 m³/h15 W33.1 dB(A)11145
You are viewing this: MFO 100/4 T3-20 min, adjustable85 m³/h15 W33.1 dB(A)11146
MFO 120/5none175 m³/h20 W39.1 dB(A)11147
MFO 120/5 T3-20 min, adjustable175 m³/h20 W39.1 dB(A)11148

The size is the nominal diameter of the fan in millimetres: 90, 100 or 120 mm. The T variants have a run-on timer; all their other data are the same as those of the basic model of the same size. The table shows the air flow of the fan in free air, which the resistance of the duct reduces.

Why choose this fan?

Vortice Punto Four MFO wall axial fan in white with a flat front panel, the exhaust sleeve at the side (manufacturer photo)

Flat front panel, hidden wall opening

The flat front panel hides the wall opening, so the installed fan is barely noticeable. The front panel is made of white, shock-proof, UV-resistant ABS plastic. It is held by a single screw, so it is easy to remove for cleaning.

Rear of the Vortice Punto Four MFO: the non-return valve in the exhaust sleeve, half open (manufacturer photo)

Non-return valve in the exhaust sleeve

A non-return valve in the exhaust sleeve prevents air and odours from flowing back when the fan is switched off. The airfoil-shaped blades of the impeller combine high performance with low noise. The motor is a shaded pole motor with thermal protection and self-lubricating sleeve bearings.

Setting the timer: turn the trimmer on the circuit board with a screwdriver (manufacturer figure)

Run-on timer

The T model switches on automatically a few seconds after the light is switched on and, after the light is switched off, keeps running for the set time of 3-20 minutes. The run-on timer is factory-set to 3 minutes; during installation you can change it to between 3 and 20 minutes. To set it, remove the front panel and turn the trimmer on the circuit board with a screwdriver.

Vortice Punto Four MFO on a bathroom wall above the bathtub (manufacturer photo)

For bathrooms and WCs

Thanks to its IPX4 rating, meaning it is protected against splashing water, it is also suitable for ventilating bathrooms, WCs and other utility rooms. It is protection class II, so no earthing is required. The extracted air may be at most 50 °C.

The Vortice Punto Four MFO seen diagonally from the front, with the short exhaust sleeve behind it (manufacturer photo)

Short sleeve, small installation depth

The exhaust sleeve is short, so a 90° bend can be connected directly behind it. The air must be discharged directly outside or through a duct no longer than 400 mm, because performance drops in longer ducts or in ducts with high resistance.

Vortice Punto Four MFO mounted on a ceiling (illustration)

For walls and ceilings

It can be installed on walls, ceilings and false ceilings. On a ceiling, install it only with the gasket of the separately available Vortice SF kit, as this is the only way to keep the IPX4 rating. The SF 90-100 kit (22162) fits the 90 and 100 sizes, and the SF 120 kit (22163) fits the 120 size.

Technical data

FeatureValue
TypeVortice Punto MFO 100/4 T, code 11146
Nominal diameter100 mm
Air flow in free air85 m³/h (24 l/s)
Maximum pressure29 Pa (3.0 mmH2O)
Speed2,400 rpm
Absorbed power15 W
Absorbed current0.09 A
Sound pressure33.1 dB(A), measured at 3 m
Sound power (LWA)54 dB(A)
Timer3-20 min, factory setting 3 min
Weight0.575 kg
Supply voltage220-240 V, 50 Hz, single-phase
Motorshaded pole, with thermal protection and self-lubricating sleeve bearings
Impelleraxial, with airfoil-shaped blades
Front panelwhite, shock-proof, UV-resistant ABS plastic
Non-return valvein the exhaust sleeve
IP ratingIPX4
Protection classII (earthing not required)
Ambient temperature in continuous operationmax. 50 °C
Mountingwall, ceiling (with SF kit), false ceiling

The data according to the ErP Regulation (1254/2014/EU) are in the ErP table of the English catalogue pages. The manufacturer is Vortice of Italy.

Dimensions

Letters as in the manufacturer drawing, dimensions in millimetres.

Dimensional drawing of the Vortice Punto Four MFO with the letters A, B, C and ØD (manufacturer drawing)
  • A: width of the front panel.
  • B: how far the fan protrudes from the wall surface, from the back of the base plate to the front of the front panel.
  • C: total depth from the end of the exhaust sleeve to the front of the front panel.
  • ØD: outside diameter of the exhaust sleeve.
SizeABCØDWall opening ØHole spacing
MFO 90/3.5158379792.495133
MFO 100/4158379798.4102133
MFO 120/517842.3114118.9122153

The front panel of the MFO 100/4 is 158 mm wide and the outside diameter of the exhaust sleeve is 98.4 mm. The wall needs an opening of 102 mm diameter, and the four fixing holes are at the corners of a 133 mm square.

Performance curve

Pressure and absorbed power as a function of air flow.

Performance curve of the Vortice Punto MFO 100/4: pressure (Pa) and absorbed power (W) as a function of air flow (m³/h) (manufacturer curve)

The thin line shows the pressure of the fan (Pa, left scale) and the thick line its absorbed power (W, right scale) as a function of air flow (m³/h, bottom scale). The curve applies to both variants of the MFO 100/4.

Installation and connection

Positioning, wall opening, mounting and electrical connection.

Installation

The fan must be installed higher than 2.3 m (manufacturer figure)
  • The fan must be installed more than 2.3 m above the floor.
  • If the fan is installed where the wall meets the tiling, a spacer must compensate for the difference in level.
  • The impeller must not be reachable by hand from the outlet side; if it is, a protective grille must be fitted.
  • Enough fresh air must be able to enter the room.
  • If an open-flued gas appliance or other combustion appliance operates in the same room, the air supply must be sufficient for all of them, and flue gas must be prevented from flowing back into the room.

Wall opening and fixing

The diameter of the wall opening and the spacing of the four fixing holes are shown in the figures and in the dimension table.

Wall opening diameter: 95 mm for size 90, 102 mm for size 100 and 122 mm for size 120 (manufacturer figure)The four fixing holes: 6 mm drill bit, 133 mm spacing for sizes 90 and 100, 153 mm for size 120 (manufacturer figure)

Installation steps

Removing the front panel: undo the screw at the bottom, then tilt the front panel forward (manufacturer figure)
  1. Remove the front panel: undo the fixing screw at the bottom and tilt the panel forward.
  2. Make the wall opening according to the dimension table.
  3. Mark the four holes, drill them with a 6 mm drill bit and insert the wall plugs.
  4. Feed in the power cable and screw the fan to the wall.
  5. Connect it according to the wiring diagram; the stripped end of the wire must be no longer than 8 mm.
  6. Refit the front panel and switch the power back on.

Electrical connection

Wiring of the T model: N1, L2 and terminal 3 from the light switch, two-pole switch (manufacturer drawing)
  • Installation and connection may only be carried out by a qualified electrician.
  • It must be connected to the mains through an omnipolar switch with a contact opening of at least 3 mm, which fully disconnects the circuit under overvoltage category III conditions.
  • The supply voltage must match the value on the fan's rating plate.
  • On the T model, besides terminals N1 and L2, the wire from the light switch goes to terminal 3, so the fan starts together with the light.

Maintenance

Cleaning with the power disconnected.

Cleaning: switch off the circuit breaker, remove dust with a brush, do not immerse the front panel in water (manufacturer figures)
  • Before cleaning, switch off the main switch or the circuit breaker.
  • Dust the front panel and the openings with a soft brush.
  • Do not immerse the front panel in water.
  • If the fan has to be dismantled for cleaning, leave this to a qualified technician.
  • If the fan has been dropped or has suffered a heavy impact, have it checked by a qualified technician before use.

What is it not suitable for?

Limits of use.

  • It must not be installed outdoors and must not be exposed to rain or sun.
  • The air conveyed must not contain grease, soot, chemicals, or corrosive, explosive or flammable substances.
  • It must not be used near flammable vapours such as alcohol, insecticides or petrol.
  • It is not designed to activate water heaters or heating appliances, and it must not discharge into hot-air flues.
  • Do not cover the inlet and outlet openings.
  • We do not recommend it for continuous operation, as this shortens its service life.

Manufacturer's documents

The English chapter of the instruction manual contains the safety instructions, its figures show installation, wiring and cleaning, and the English catalogue pages give the technical data, performance curves and accessories.

Instruction manual (21 languages, including English)Catalogue pages (English)

Accessories for installation

Gravity shutters, rain guard grilles, PVC pipes and aluminium tape from our online shop; our staff will help you choose the right size.

The Nemes Ventilátorház team

Buy from one of Hungary's most trusted ventilation specialists

Ventilátorház is located at Királyhágó utca 30 in Budapest's XVIII. district. We are a multi-award-winning company with decades of experience. Our expert staff will help you with sizing and choosing accessories. Call them on +36-70-369-9944.

Request free adviceCall now

Frequently asked questions

The MFO 100/4 needs a wall opening of 102 mm diameter. The outside diameter of the sleeve is 98.4 mm; the other dimensions are given in the dimension table.

To a duct of up to 400 mm, or it can discharge directly outside. Our staff will help you choose.

Yes, but only with the gasket of the Vortice SF ceiling kit, which is not included.

For the set time, between 3 and 20 minutes; the factory setting is 3 minutes.

The Vortice C 1.5 controller is only for the basic models; there is no manufacturer speed controller for the T model.

No, it is double insulated.

We do not recommend it, because continuous operation shortens its service life. The other limits of use are listed in the What is it not suitable for? section.

In free air, measured at 3 m, its sound pressure is 33.1 dB(A).

Yes, for example the Vortice MICRO 100 centrifugal fan.

We also recommend the following product as an accessory

Tartozékok ehhez a termékhez

Customer account
  • Sign In
  • Sign Up
  • My Profile
  • Cart
  • My Favorites
Information
  • Terms and Conditions
  • Privacy Policy
  • Payment
  • Shipping
  • Contact details
  • Blog
  • facebook

WebShop System
simplepay_hu_v2
viva_com
  • Bathroom and toilet extractor fans
  • Window Fans
  • Cooker hoods
  • Industrial ventilation accessories
  • Industrial ventilation
  • Commercial kitchen extract fans
  • In-line duct fans
  • Centrifugal fans (low pressure)
  • Heat Recovery Systems
  • PVC heat recovery distribution boxes and valve plenums
  • Metal heat recovery distribution boxes and valve plenums
  • Heat recovery system installation materials
  • Metal fittings
  • Metal ducts (rigid and flexible)
  • Duct heaters
  • Silencers
  • Air inlets
  • Air valves
  • Instrument fans
  • Butterfly dampers
  • Rigid round PVC ducts and fittings
  • Rigid rectangular PVC ducts and fittings
  • Flexible PVC ducts
  • Grilles and louvres
  • Fixing and suspension clamps
  • Controllers and electronics
  • Installation accessories
  • Insulated rigid ducts and fittings
  • Insulation materials
  • Access doors
  • Filter boxes and filter media
  • Roof terminals and roof cowls
  • Fire protection products
  • Fan accessories
  • Backdraught shutters
  • Fan filters
Change language
  • hu
  • en
  • de
Change currency
Sign in
Sign Up
Privacy settings
Our website uses cookies necessary for basic functionality. You can allow additional cookies for broader features (marketing, analytics, personalization). For more details, see our Privacy Policy in the Privacy Notice.
Essential cookies are critical for the website’s core functions, and the site will not work properly without them. These cookies do not store personally identifiable information.
We use marketing cookies to track visitors’ activity on the site. The goal is to show relevant ads to individual users (e.g., via Google Ads and Facebook Ads) and encourage engagement, making our website more valuable.
Statistical cookies help the website owner understand how visitors interact with the site by collecting and reporting data anonymously.
Personalization cookies let us remember information that changes how the website behaves or looks.