VENTS 100 Quiet small-room fan
The VENTS 100 Quiet small-room fan is an axial fan for small rooms such as bathrooms, toilets and pantries. It delivers 97 cubic metres of air per hour with a 100 mm duct diameter, and its sound pressure measured at 3 metres is 25 dB(A).
It is available in standard, timer (T) and humidity sensor (TH) versions, with the same airflow and noise level. You can choose the version with the buttons above or from the table in the description. It has a built-in backdraught damper, is rated IP45, can be mounted on the wall or ceiling, and can also be installed in the first, second and third zones of the bathroom. Our expert staff will help you with sizing and choosing accessories.

VENTS 100 Quiet small-room fan in standard, timer and humidity sensor versions
The VENTS 100 Quiet small-room fan is a quiet 100 mm extract fan from the VENTS Quiet series, for bathrooms, toilets and pantries. It is designed for extracting air from small and medium-sized rooms. You will find more models in our axial small-room fan category.
It delivers 97 cubic metres of air per hour with a 100 mm duct diameter, and its sound pressure measured at 3 metres is 25 dB(A). Its power consumption is 7.5 W.
In our webshop it is available in standard, timer (T) and humidity sensor (TH) versions; the three versions have the same performance and size, only their control differs.
Which version do you need?
This is how the versions of the VENTS 100 Quiet differ.
| Version | Model | Control | Air flow rate | Sound pressure at 3 m | Power |
|---|---|---|---|---|---|
| VENTS 100 Quiet | Quiet 100 | external switch | 97 m³/h | 25 dB(A) | 7.5 W |
| VENTS 100 Quiet T | Quiet 100 T | run-on time 2-30 minutes | 97 m³/h | 25 dB(A) | 7.5 W |
| VENTS 100 Quiet TH | Quiet 100 TH | humidity sensor 60-90%, run-on time 2-30 minutes | 97 m³/h | 25 dB(A) | 7.5 W |
- Standard. The standard version runs only with the external switch: it starts and stops together with it.
- With timer (T). The version with timer keeps running for another 2-30 minutes after switching off.
- With humidity sensor (TH). The version with humidity sensor starts automatically above the humidity level set in the 60-90% range, and keeps running for 2-30 minutes after the humidity has dropped.
A thyristor speed controller can only be connected to the standard version, not to the versions with timer or humidity sensor.
Why choose this fan?

Quiet operation, ball-bearing motor
The motor sits on anti-vibration dampers, and air rectifiers in the exhaust spigot reduce turbulence, pressure loss and noise. The motor has ball bearings, and the maintenance-free bearings contain enough grease for 40 000 hours of continuous operation.

Into a ventilation shaft or a duct, with backdraught damper
It discharges the air directly into the ventilation shaft or into the shaft through a 100 mm duct. The fan must not be installed so that it discharges the air straight upwards.
The built-in backdraught damper prevents air from flowing back and heat from being lost when the fan is not running.

IP45 rating, sealed electronics
It is rated IP45, the electronics are protected by a sealed cover, and the motor has overheating protection.

UV-resistant plastic, removable front panel
The casing and the impeller are made of UV-resistant plastic. The front panel is held on the casing by latches; for cleaning it can be released with a screwdriver and removed.
Technical data
| Parameter | Value |
|---|---|
| Air flow rate | 97 m³/h (free air) |
| Sound pressure | 25 dB(A), in free space, at 3 m |
| Sound power (ErP) | 45 dB(A) |
| Power consumption | 7.5 W |
| Current consumption | 0.049 A |
| Supply voltage | 220-240 V, 50 Hz |
| IP rating | IP45 (assembled) |
| Protection class | Class II, no earthing required |
| Ambient temperature | from +1 °C to +40 °C |
| Connected air duct size | Ø100 mm (spigot Ø99 mm) |
| Weight | 0.55 kg |
| Bearing | ball bearing, maintenance-free |
| Backdraught damper | built in |
| Mounting | on the wall and ceiling, with screws; 4 screws and dowels included |
| Run-on time (T, TH) | 2-30 minutes, adjustable |
| Humidity sensor (TH) | 60-90% relative humidity, adjustable |
| Model | Quiet 100, Quiet 100 T, Quiet 100 TH |
Dimensions
All dimensions are in millimetres.

| Dimension | ØD | B | H | L | L1 |
|---|---|---|---|---|---|
| mm | 99 | 158 | 136 | 81 | 26 |
The square front panel measures 158 × 158 mm and is 26 mm deep (B and L1); behind it, the casing and the exhaust spigot are 81 mm deep (L). The outer diameter of the exhaust spigot is 99 mm (ØD), so it fits into a 100 mm duct or ventilation shaft. The side of the rear casing that goes against the wall is 136 mm (H).
Performance curve

The curve shows the fan's pressure as a function of airflow: at free air it delivers 97 cubic metres per hour. We recommend it for duct runs of up to 1.5 metres; for longer ducts we offer centrifugal bathroom extractor fans.
Where can it be installed?

- The fan can be mounted on the wall or on the ceiling.
- If the ventilation shaft is further away, a flexible duct can also be connected, fixed to the exhaust spigot with a clamp.
- It can also be installed in zones 1, 2 and 3 of the bathroom, provided that the installation and wiring comply with IEC 60364-7-701 and the national regulations.
- If the duct leads outdoors through the wall, we recommend a gravity shutter on the outside so that cold air does not come back into the duct.
- We recommend it for bathrooms, toilets, pantries and other rooms in the home, for domestic use.
Wiring and setting
- The wiring diagram is shown on the product page of each version and in the operating instructions: on the standard version the external switch switches the phase, while the T and TH versions receive a permanent supply and a switched phase.
- The electrical connection may only be carried out by a qualified electrician.
- It must be connected to the mains via an all-pole disconnecting switch.
Maintenance and safety

- We recommend maintenance at least every six months: after disconnecting the power, remove the front panel and wipe the fan with a dry cloth or brush; the front panel can be washed under running water.
- Water must not come into contact with electrical parts.
- Next to open-flue gas or other fuel-burning appliances, backflow of flue gas into the room must be prevented; after installation, a specialist must check the operation of the fuel-burning appliance.
- The conveyed air must not contain dust, sticky substances or fibrous contaminants.
- The fan may only be installed after the construction and finishing work in the room has been completed.
Manufacturer's documents
The manufacturer's data sheet shows the technical data, performance curve and dimensional drawing of the Quiet 100, and the English-language operating instructions describe installation, wiring, setting and maintenance.
Accessories for the 100 mm duct
We recommend these gravity shutters, ducts, clamps and rain-protection grilles for it.

Buy from one of Hungary's most trusted ventilation specialists
Ventilátorház is located at Királyhágó utca 30 in Budapest's XVIII. district. We are a multi-award-winning company with decades of experience. Our expert staff will help you with sizing and choosing accessories. Call them on +36-70-369-9944.
Frequently asked questions
The three versions have the same airflow, noise level and size, only their control differs; see the table of versions.
The outer diameter of the exhaust spigot is 99 mm, so it is suitable for a 100 mm duct or ventilation shaft.
Yes, it can be mounted on the wall or on the ceiling; the figure showing the installation options is above.
Yes, it can also be installed in zones 1, 2 and 3 of the bathroom; the conditions are given below the zone diagram.
Yes, the backdraught damper is factory-fitted. If the duct leads outdoors through the wall, we also recommend a gravity shutter on the outside.
Only the standard version, with a thyristor speed controller; the details are given below the table of versions.
In the current VENTS range, the successor of the Quiet 100 is the Quiet-X 100, with the same dimensions. It delivers 98 cubic metres per hour with a sound pressure of 24 dB(A) and a power consumption of 7 W. Please ask our staff which model is supplied.