Nemes Ventilátorház

Kérdése van? +36-70-369-9944

Categories
Nemes Ventilátorház

Kérdése van? +36-70-369-9944

  • Categories
    • Bathroom and toilet extractor fans
    • Window Fans
    • Cooker hoods
    • Industrial ventilation accessories
    • Industrial ventilation
    • Commercial kitchen extract fans
    • In-line duct fans
    • Centrifugal fans (low pressure)
    • Heat Recovery Systems
    • PVC heat recovery distribution boxes and valve plenums
    • Metal heat recovery distribution boxes and valve plenums
    • Heat recovery system installation materials
    • Metal fittings
    • Metal ducts (rigid and flexible)
    • Duct heaters
    • Silencers
    • Air inlets
    • Air valves
    • Instrument fans
    • Butterfly dampers
    • Rigid round PVC ducts and fittings
    • Rigid rectangular PVC ducts and fittings
    • Flexible PVC ducts
    • Grilles and louvres
    • Fixing and suspension clamps
    • Controllers and electronics
    • Installation accessories
    • Insulated rigid ducts and fittings
    • Insulation materials
    • Access doors
    • Filter boxes and filter media
    • Roof terminals and roof cowls
    • Fire protection products
    • Fan accessories
    • Backdraught shutters
    • Fan filters
Helios M1/120 F MiniVent small room fan
Helios M1/120 F MiniVent small room fan
286 €
  1. Bathroom and toilet extractor fans
  1. Bathroom and toilet extractor fans

Helios M1/120 F MiniVent small room fan

Helios M1/120 F MiniVent small room fan
Helios M1/120 F MiniVent small room fan
Helios M1/120 F MiniVent small room fan
Helios M1/120 F MiniVent small room fan
Helios M1/120 F MiniVent small room fan
Helios M1/120 F MiniVent small room fan
Helios M1/120 F MiniVent small room fan
Helios M1/120 F MiniVent small room fan
286 €

The Helios M1/120 F MiniVent axial small room fan starts via its humidity control function: the electronics switch it on according to the rate of humidity increase, and the limit value can be set to 60, 70, 80 or 90 per cent. At high level its volume flow is 170 cubic metres per hour and at low level 150 cubic metres per hour, and in this operating mode its noise level at a distance of 3 metres is 32 dB(A). Its connection spigot is Ø118 mm, for 120 and 125 ducts.

It is developed in Germany by Helios, its impeller runs on ball bearings, the backdraught shutter is fitted as standard in its spigot, and its completely closed facade conceals the dirty fan opening. With protection category IPX5 it can also be installed near the shower. Our expert staff will help you with sizing and choosing accessories.

Diameter Diameter:
100
125
150
Convenience Features Convenience Features:
Standard
Run-on timer
Humidity-controlled
PIR sensor
Max. Airflow Max. Airflow:
170 m3/h
100 napos pénzvisszafizetési garancia
100 napos visszafizetési garancia
Tudjon meg többet!
Ingyenes légtechnikai tanácsadás
Országos kiszállítás
akár másnapra
Mindössze 2500 forintért
Data
Type of Airflow:
Axial
Availability:
In stock
Diameter:
125
Convenience Features:
Humidity-controlled
Mounting Method:
Wall and ceiling
Noise Level:
Quiet
Max. Airflow:
170 m3/h
Manufacturer:
Helios
Bearing Type:
Ball bearing
Speed Levels:
Multi-speed
Louvre:
Backdraught shutter
Pipe Insertable:
No
Protection:
IPX5
Colour:
White
Material:
Plastic housing
Max. pressure:
53 Pa
Voltage:
230
Size:
176 x 176
EAN:
4010184063643
Number of phases:
1
Motor poles:
2
Max. current consumption:
0.09 A
Weight:
1.05
Power consumption:
13 W
Rated speed (rpm):
2 350
Air temperature range (°C):
max. +40
Manufacturer's part number:
06364
Product family:
Helios MiniVent M1
Sound pressure at 3 m (dB(A)):
36
Website:
https://www.heliosventilatoren.de/de/produkte/klei...
Professzionális bemutatóterem
Professzionális bemutatóteremPróbálja ki termékeinket Budapesten, a Királyhágó utca 30. alatt
Ingyenes szaktanácsadás
Ingyenes szaktanácsadásTapasztalt és segítőkész szakembereink várják hívását
Megbízható kereskedő
Megbízható kereskedő32 év tapasztalatával az ország egyik legnagyobb forgalmazója
Díjnyertes vállalkozás
Díjnyertes vállalkozásDíjainkat és kiemelkedő értékeléseinket tisztességes üzletvitelünk miatt kaptuk
Details

Helios M1/120 F MiniVent: with humidity control function, it starts automatically

The Helios M1/120 F MiniVent axial small room fan is the premium class of the German manufacturer's small room fans. At low level it moves 150 cubic metres of air per hour, and in this operating mode its noise level at a distance of 3 metres is 32 dB(A) — this is thanks to Helios ultraSilence technology. At high level its volume flow is 170 cubic metres per hour; its connection spigot is Ø118 mm, so it connects to 120 and 125 ducts. This size is suitable for a larger room of approximately 12–20 square metres. If the air has to pass through a duct and an external shutter, the volume flow is lower: the manufacturer's figure is 120 cubic metres per hour at 31 pascals of resistance.

With this variant you do not need to think about the switch: the electronics switch the fan on according to the rate of humidity increase, so it starts when the humidity begins to rise during a shower. The limit value can be set to 60, 70, 80 or 90 per cent. The length of the turn-off delay depends on how quickly the room humidity is reduced, and if the humidity remains constantly high, the unit automatically switches to interval mode. For manual operation the turn-off delay is 6, 12, 18 or 24 minutes.

The manufacturer recommends this size for small to medium-sized rooms, in private buildings just as in commercial or industrial buildings: for bathrooms, washrooms, changing rooms, utility rooms and kitchenettes. This unit is not suitable for ventilating large retail premises, workshops or warehouses — they need an industrial fan, and we will gladly help you with that too. The M1 series is developed in Germany by Helios; its front facade is completely closed, a multi-award-winning design, and the air flows in from all sides — so it conceals the dirty fan opening, and the smooth surface can be kept clean with a single wipe.

Data sheet

The official Helios catalogue page contains the technical data of all three sizes and all versions of the MiniVent M1, the performance curves, the dimensional drawings and the wiring diagram numbers. It is useful for electricians, architects and anyone looking for precise data for the installation. The manufacturer's part number (ref. no.) of this version is 06364.

Download the manufacturer's data sheet The manufacturer's page
Helios M1/120 F MiniVent exploded view: facade, impeller, guide wheel, backdraught shutter
i

Did you know? If the room has a suspended ceiling and you want to route the ventilation duct above the ceiling, this is not the right choice — that calls for a centrifugal fan with a recessed casing, even if the duct run is short. The M1 is designed to ventilate through the wall, via a short duct, directly outdoors.

Technical data

Comparison of the four Ø120 versions; highlighted: the variant you are viewing.

M1/120M1/120 N/CM1/120 FM1/120 P
Ref. no.06360063610636406363
VersionStandard model with two speed levelsTurn-off delay and interval modeWith humidity control functionWith presence detector
Flow rate free blowingm³/h170 / 150
Volume flow at 31 Pa resistancem³/h120
Maximum pressurePa53
Power consumptionW13 / 10
Rated currentA0.09 / 0.08
Sound pressure level at 3 mdB(A)36 / 32
Speed1/min2350 / 2050
Impeller diametermm111
Connection spigotmmØ118 (for 120 and 125 ducts)
Voltage / frequency / phaseV / Hz230 / 50 / 1
Turn-off delay time, adjustablemin–6, 10, 15, 216, 12, 18, 246
Interval mode, adjustableh–0, 8, 12, 24––
Start-up delays–0, 45, 90, 1200 or 45–
Humidity limit value, adjustable%––60, 70, 80, 90–
Backdraught shutterFitted as standard, removable
Electrical supply line NYM-Omm²3 × 1.54 × 1.54 × 1.53 × 1.5
Wiring diagram no.915917919918
Protection categoryIPX5, protection class II
Max. air flow temperature°C+40
Weightkg1.05

Dimensions

All dimensions in millimetres

Helios M1/120 F MiniVent dimensional drawing

The facade measures 176 × 176 mm and projects 39 mm from the wall. The connection spigot is Ø118 mm. The unit is installed 116 mm deep into the wall; in case of restricted space conditions the guide wheel can be removed, which reduces the installation depth to 70 mm. The drilling distance of the fastening screws is 141.5 mm, and the required wall opening is 140 mm.

Performance curve

Click the image to enlarge

Helios M1/120 F MiniVent performance curve

M1/120 — high and low level

The curve shows how much air the fan delivers as a function of the back pressure, calculated for an air density of 1.20 kg/m³. With free blowing at high level it delivers 170 cubic metres per hour, at 31 pascals of resistance 120 cubic metres per hour, and its maximum pressure is 53 pascals. The volume flow of the four Ø120 versions is identical — the difference lies in the electronics, not in the fan.

Why do we recommend it?

The humidity control function responds to the rate of increase

According to the manufacturer, the intelligent electronics monitor the rate of humidity increase and thus effectively prevent mould formation. In practice this means that the fan starts at the beginning of the shower and runs until the humidity has cleared — it is not a switch or a timer that decides how long the room needs to be ventilated.

The backdraught shutter is fitted as standard

The connection spigot contains the tight-closing backdraught shutter, which is not standard equipment in every small room fan. When the fan stops, the shutter closes, so no cold air is drawn into the room through the duct. The shutter can be removed if the installation requires it.

Ball-bearing motor, in any mounting position

The ball bearings are designed for 40 000 operating hours, so the unit works in any position, even directly in the ceiling. The motor has thermal overload protection, and the manufacturer describes it as maintenance-free — however, regular cleaning of the impeller is necessary for this fan too; without it, any fan wears out sooner.

Also for wet room zone 1

It is made with jet water protection IPX5 and protection class II, so it can be installed in zone 1 according to DIN VDE 0100-701, i.e. also near the shower and the bathtub. The electrical connection is made easier by screwless terminals and the circumferential cable storage space of the casing.

Accessories for this product

For Ø125 installation, from our online shop

Frequently Asked Questions

At high level, with free blowing, it moves 170 cubic metres of air per hour, which is sufficient for a room of approximately 12–20 square metres — a larger bathroom, a utility room, a changing room or a washroom in a commercial building. In practice, the resistance of the duct run and the external shutter reduces this figure: the manufacturer's figure is 120 cubic metres per hour at 31 pascals of resistance. We will gladly help you with sizing.

It does not react to a single fixed humidity value, but to the rate of humidity increase — this is why it starts during a shower. In addition, the limit value can be set to 60, 70, 80 or 90 per cent; the setting is made by the qualified electrician inside the unit. The turn-off delay time depends on the room humidity reduction; for manual operation it is 6, 12, 18 or 24 minutes. A 4 × 1.5 mm² cable is required for the connection, and the manufacturer's wiring diagram number is 919.

The volume flow and the spigot size. The 100 delivers 90 cubic metres per hour with a Ø100 spigot, the 120 delivers 170 cubic metres per hour with a Ø118 spigot (for 120 and 125 ducts), and the 150 delivers 260 cubic metres per hour with a Ø145 spigot. The casing also grows: the facade is 147, 176 and 210 mm respectively. For an existing duct diameter, always choose the matching size, because reducing or enlarging creates back pressure, and this costs volume flow.

The ball-bearing motor is designed for 40 000 operating hours, so the unit works in any mounting position — even directly in the ceiling. However, if there is a suspended ceiling and you want to route the ventilation duct above the ceiling, this is not the right choice: that calls for a centrifugal fan with a recessed casing, even if the duct run is short.

No. An axial fan cannot cope with the pressure in the common stack: either it pushes the air back into the room, or it cannot extract it. A common exhaust stack needs a centrifugal fan designed for duct systems. This unit is designed to ventilate through the wall, via a short duct, directly outdoors.

Yes. The unit is made with jet water protection IPX5 and protection class II, so it can also be used in zone 1 according to DIN VDE 0100-701 — i.e. also in the part of the wet room close to the shower. The electrical connection should be carried out by a qualified electrician.

We also recommend the following product as an accessory

Tartozékok ehhez a termékhez

A Nemes Ventilátorház csapata

Vásároljon Magyarország egyik legmegbízhatóbb légtechnikai áruházából

A Ventilátorház Budapest XVIII. kerületében, a Királyhágó utca 30. alatt található. Sokszoros díjnyertes cég vagyunk, több évtizedes tapasztalattal. A méretezésben és a tartozékok kiválasztásában szakértő munkatársaink segítenek — hívja őket a +36-70-369-9944 telefonszámon.

Ingyenes tanácsadást kérek Felhívom most
Customer account
  • Sign In
  • Sign Up
  • My Profile
  • Cart
  • My Favorites
Information
  • Terms and Conditions
  • Privacy Policy
  • Payment
  • Shipping
  • Contact details
  • Blog
  • facebook

WebShop System
simplepay_hu_v2
viva_com
  • Bathroom and toilet extractor fans
  • Window Fans
  • Cooker hoods
  • Industrial ventilation accessories
  • Industrial ventilation
  • Commercial kitchen extract fans
  • In-line duct fans
  • Centrifugal fans (low pressure)
  • Heat Recovery Systems
  • PVC heat recovery distribution boxes and valve plenums
  • Metal heat recovery distribution boxes and valve plenums
  • Heat recovery system installation materials
  • Metal fittings
  • Metal ducts (rigid and flexible)
  • Duct heaters
  • Silencers
  • Air inlets
  • Air valves
  • Instrument fans
  • Butterfly dampers
  • Rigid round PVC ducts and fittings
  • Rigid rectangular PVC ducts and fittings
  • Flexible PVC ducts
  • Grilles and louvres
  • Fixing and suspension clamps
  • Controllers and electronics
  • Installation accessories
  • Insulated rigid ducts and fittings
  • Insulation materials
  • Access doors
  • Filter boxes and filter media
  • Roof terminals and roof cowls
  • Fire protection products
  • Fan accessories
  • Backdraught shutters
  • Fan filters
Change language
  • hu
  • en
  • de
Change currency
Sign in
Sign Up
Privacy settings
Our website uses cookies necessary for basic functionality. You can allow additional cookies for broader features (marketing, analytics, personalization). For more details, see our Privacy Policy in the Privacy Notice.
Essential cookies are critical for the website’s core functions, and the site will not work properly without them. These cookies do not store personally identifiable information.
We use marketing cookies to track visitors’ activity on the site. The goal is to show relevant ads to individual users (e.g., via Google Ads and Facebook Ads) and encourage engagement, making our website more valuable.
Statistical cookies help the website owner understand how visitors interact with the site by collecting and reporting data anonymously.
Personalization cookies let us remember information that changes how the website behaves or looks.