Maico ECA 100 ipro KB two-step small room fan with electric internal shutter and motion detector, DN 100, article number 0084.0209
The Maico ECA 100 ipro KB small room fan starts automatically with its motion detector when someone enters, and stops after the set overrun time. It delivers 78 or 92 cubic metres of air per hour with a DN 100 duct diameter, with a sound pressure of 27 or 32 dB(A) at 3 metres, which is enough to ventilate a bathroom, WC or storeroom, according to the manufacturer up to 30 square metres. It comes with an electrically operated internal shutter.
Thanks to its IP rating of IP X5, it can also be installed in protection area 1 next to the shower, on both the wall and the ceiling, and it can replace the earlier ECA DN 100 models without modification. Our expert staff will help you with installation and choosing accessories.
Small room fan with electric internal shutter and motion detector
The Maico ECA 100 ipro KB small room fan starts automatically with its motion detector when someone enters, and stops after the set overrun time.
Behind the concealed air intake there is an electrically operated internal shutter. According to the manufacturer's ErP data sheet, the indoor / outdoor air tightness of this series is 7 cubic metres per hour, compared with 41 for the variants without a shutter, with a fixed internal grille.
It is two-step: free-blowing, it delivers 78 cubic metres of air per hour at level 1 and 92 at level 2 with a DN 100 duct diameter. According to the factory measurement, its sound pressure at 3 metres is 27 and 32 dB(A) respectively. It is designed to ventilate bathrooms, WCs, storage rooms, larders or cellars, according to the manufacturer for rooms up to 30 square metres.
Which variant do you need?
The name leads to the product page
| With fixed internal grille | With electric internal shutter (K) | |
|---|---|---|
| Standard model: via switch, level 1 or 2 | Maico ECA 100 ipro | Maico ECA 100 ipro K |
| Timer: start delay + overrun time | Maico ECA 100 ipro VZC | Maico ECA 100 ipro KVZC |
| Light control: light sensor | Maico ECA 100 ipro F | Maico ECA 100 ipro KF |
| Humidity control: humidity sensor | Maico ECA 100 ipro H | Maico ECA 100 ipro KH |
| Motion detector: motion sensor | Maico ECA 100 ipro B | You are viewing this: Maico ECA 100 ipro KB |
The fan, air flow rate and noise of the ten variants are the same; they differ in two things: whether they have an electric internal shutter and what starts them. The letter K stands for the shutter, the other letters for the control: VZC timer, F light control, H humidity control, B motion detector. The selector on the product page asks the same two questions, in the “Internal shutter” and “Convenience function” rows.
Technical data
All ten variants according to Maico's product data sheets. The variant you are viewing is highlighted in the table.
| Variant | Manufacturer's part number | Control | Internal shutter | Power, level 1/2 (W) | Max. current consumption (A) | Weight (kg) | EAN |
|---|---|---|---|---|---|---|---|
| Maico ECA 100 ipro | 0084.0200 | Standard model | none (fixed grille) | 6 / 8 | 0.06 | 0.70 | 4012799842002 |
| Maico ECA 100 ipro VZC | 0084.0201 | Timer | none (fixed grille) | 6 / 8 | 0.06 | 0.71 | 4012799842019 |
| Maico ECA 100 ipro F | 0084.0202 | Light control | none (fixed grille) | 6 / 8 | 0.06 | 0.72 | 4012799842026 |
| Maico ECA 100 ipro H | 0084.0203 | Humidity control | none (fixed grille) | 6 / 8 | 0.06 | 0.71 | 4012799842033 |
| Maico ECA 100 ipro B | 0084.0204 | Motion detector | none (fixed grille) | 6 / 8 | 0.06 | 0.71 | 4012799842040 |
| Maico ECA 100 ipro K | 0084.0205 | Standard model | electric | 10 / 13 | 0.08 | 0.74 | 4012799842057 |
| Maico ECA 100 ipro KVZC | 0084.0206 | Timer | electric | 10 / 13 | 0.08 | 0.73 | 4012799842064 |
| Maico ECA 100 ipro KF | 0084.0207 | Light control | electric | 10 / 13 | 0.08 | 0.74 | 4012799842071 |
| Maico ECA 100 ipro KH | 0084.0208 | Humidity control | electric | 10 / 13 | 0.08 | 0.74 | 4012799842088 |
| Maico ECA 100 ipro KB | 0084.0209 | Motion detector | electric | 10 / 13 | 0.08 | 0.74 | 4012799842095 |
| Air flow rate, level 1 / 2, free-blowing | 78 / 92 m³/h |
|---|---|
| Speed, level 1 / 2 | 2100 / 2500 rpm |
| Sound pressure at 3 m, free field, level 1 / 2 | 27 / 32 dB(A) |
| Sound power (ErP data sheet) | 45 dB(A) |
| Nominal size | DN 100 (outer diameter of the socket 99 mm) |
| Size (width × height × depth) | 159 × 159 × 130 mm |
| Voltage / frequency | 230 V / 50 Hz, alternating current |
| IP rating | IP X5, also for protection area 1 according to DIN VDE 0100-701 |
| Protection class | II. |
| Airstream temperature | up to 40 °C |
| Motor | ball bearings, maintenance-free, with thermal overload protection; suitable for continuous operation |
| Speed control | only on the standard model and the K (Maico STX 1.5 / STX 2.5) |
| Installation | on the wall or ceiling, surface-mounted, in any position; the cable is fed in flush-mounted |
| Mains cable | 3 × 1.5 or 5 × 1.5 mm² (timer VZC and KVZC: 5 × 1.5 mm²) |
| Housing | impact-resistant plastic, traffic white (similar to RAL 9016) |
The upper table shows the data that differ between the variants, the lower one the data that are the same for all ten variants. The power consumption of the K series is higher; the air flow rate and the noise are the same. At a different measuring point, the manufacturer's ErP data sheet gives a maximum air flow volume of 81 cubic metres per hour, or 79 for the K series; 78 / 92 is the free-blowing value of the characteristic curve.
How does it start and stop?
According to the manufacturer's installation instructions
With its motion detector, it switches on and off automatically. The sensor has a range of 5 metres and a detection angle of 100 degrees horizontally and 82 degrees vertically. It works without a switch, but it can also be switched with a separate switch. It has no start delay; the overrun time is 0, 8, 17 or 25 minutes, factory setting 8. The overrun time can be set with the setting button on the unit, and LEDs show the set value. The manufacturer calls it a barrier-free product because it switches automatically. There are four operating programmes to choose from, which the electrician sets with jumpers in the unit: in the factory-set Comfort programme it runs at level 1 during operation and at level 2 during overrun, in the Night programme the other way round, in the Economy programme at level 1 throughout, and in the Power programme at level 2 throughout.
Performance curve
From Maico's product data sheet

Curve 1 is level 1, curve 2 is level 2. The horizontal axis shows the air flow rate per hour, the vertical axis the static pressure in pascals. The longer and more winding the duct, the greater its resistance and the less air the fan delivers: 78 or 92 cubic metres free-blowing, less through a duct. The characteristic curve applies to all ten variants.
Manufacturer's data sheet
The product data sheet of the Maico ECA 100 ipro KB (0084.0209) contains the complete technical data, the characteristic curve and the dimensioned drawing. The planning instructions summarise the protection areas in bathrooms, the duct length and the air supply. Give the installation instructions to the electrician: they contain the wiring diagrams, the operating programmes and how to set the times (in German, English and French).
Dimensions
According to the manufacturer's dimensional drawing, in millimetres

The cover measures 159 × 159 millimetres and protrudes 50 millimetres from the wall. The socket is 80 millimetres long and 99 millimetres in diameter, and it fits into a DN 100 duct or wall sleeve. The two fixing holes are 129 millimetres apart both horizontally and vertically. According to the manufacturer, the fixing holes and the flush-mounted cable entry are in the same place as on the earlier ECA DN 100 models, so it can replace the old unit without modification. All ten variants have the same dimensions.
Why do we recommend it?
- Concealed air intake. It draws in air from behind the flat cover, with no visible grille. The cover can easily be removed with a tool.
- Two levels. 78 or 92 cubic metres per hour, with a sound pressure of 27 or 32 dB(A) at 3 metres.
- IP X5, protection class II. According to the manufacturer, it can also be installed in protection area 1 according to DIN VDE 0100-701, close to the bath and the shower.
- Ball-bearing motor. Maintenance-free, with thermal overload protection, also suitable for continuous operation.
- Also as a replacement unit. The fixing holes and the cable entry are in the same place as on the earlier ECA DN 100 models.
- Electric internal shutter in the K series. According to the ErP data sheet, the indoor / outdoor air tightness is 7 cubic metres per hour, compared with 41 for the variants with a fixed internal grille.
What to watch out for during installation
According to Maico's planning instructions and installation instructions
- Installation and connection must be carried out by a specialist, as the manufacturer also requires.
- According to the manufacturer's planning instructions, it is suitable for rooms up to 30 square metres, the duct may be up to approx. 5 metres long with 2 elbows, and only one room may be connected per duct. It is not suitable for central exhaust shaft systems serving several dwellings (DIN 18017-3).
- A core drill hole of at least 105 millimetres is required in the wall; the manufacturer recommends the Maico WH 100 wall sleeve, which requires a 115 millimetre hole. The wall sleeve should slope outwards by 1-2 degrees.
- Air must be able to flow into the room, for example through a door ventilation grille that cannot be closed. If the dwelling has an open-flued stove or fireplace, the manufacturer requires the chimney sweep to be consulted.
- A duct passing through unheated areas must be thermally insulated, and a condensate drain is needed for a vertical duct.
- The IP X5 degree of protection is only achieved if the electronics cover is pressed tightly into the housing all round.
- The box contains the fan, the electronics cover, a foam strip and the instructions; the manufacturer does not include fixing screws.
Accessories for this product

Buy from one of Hungary's most trusted ventilation specialists
As Maico's representative in Hungary, we offer Maico fans at importer prices. Ventilátorház is located at Királyhágó utca 30 in Budapest's XVIII. district. We are a multi-award-winning company with decades of experience. Our expert staff will help you with sizing and choosing accessories. Call them on +36-70-369-9944.
Frequently asked questions
This one has an electrically operated internal shutter, the Maico ECA 100 ipro B a fixed internal grille. According to the ErP data sheet, the indoor / outdoor air tightness is 7 cubic metres per hour here and 41 there. Its power consumption is 10 / 13 watts instead of 6 / 8; the air flow rate, the noise and the control are the same.
With its motion detector, it switches on and off automatically. The sensor has a range of 5 metres and a detection angle of 100 degrees horizontally and 82 degrees vertically. It works without a switch, but it can also be switched with a separate switch. It has no start delay; the overrun time is 0, 8, 17 or 25 minutes, factory setting 8. The overrun time can be set with the setting button on the unit, and LEDs show the set value. The manufacturer calls it a barrier-free product because it switches automatically. There are four operating programmes to choose from, which the electrician sets with jumpers in the unit: in the factory-set Comfort programme it runs at level 1 during operation and at level 2 during overrun, in the Night programme the other way round, in the Economy programme at level 1 throughout, and in the Power programme at level 2 throughout.
No, the motion detector switches it. It can also be connected to a separate switch.
For a DN 100 duct. According to the manufacturer's planning instructions, for rooms up to 30 square metres, with a duct of up to approx. 5 metres and 2 elbows. Free-blowing, it delivers 78 or 92 cubic metres per hour, less through a duct.
According to the factory measurement, in a free field at a distance of 3 metres, its sound pressure is 27 dB(A) at level 1 and 32 dB(A) at level 2. It is the same for all ten variants.
According to the manufacturer, yes: it has IP X5 protection, so it can also be installed in protection area 1 according to DIN VDE 0100-701, and it is protection class II. The connection must be made by a specialist.
According to the manufacturer, it is compatible with the earlier ECA DN 100 models: the fixing holes and the flush-mounted cable entry are in the same place, so it can be fitted in their place without modification.
Yes, on both the wall and the ceiling, in any position. The cable reaches the unit flush-mounted, from inside the wall.