Helios M1/120 N/C MiniVent small room fan
The Helios M1/120 N/C MiniVent axial small room fan keeps running for 6, 10, 15 or 21 minutes after the light is switched off, and in interval mode it ventilates automatically every 8, 12 or 24 hours. At high level its volume flow is 170 cubic metres per hour and at low level 150 cubic metres per hour, and in this operating mode its noise level at a distance of 3 metres is 32 dB(A). Its connection spigot is Ø118 mm, for 120 and 125 ducts.
It is developed in Germany by Helios, its impeller runs on ball bearings, the backdraught shutter is fitted as standard in its spigot, and its completely closed facade conceals the dirty fan opening. With protection category IPX5 it can also be installed near the shower. Our expert staff will help you with sizing and choosing accessories.
Helios M1/120 N/C MiniVent: with turn-off delay and interval mode
The Helios M1/120 N/C MiniVent axial small room fan is the premium class of the German manufacturer's small room fans. At low level it moves 150 cubic metres of air per hour, and in this operating mode its noise level at a distance of 3 metres is 32 dB(A) — this is thanks to Helios ultraSilence technology. At high level its volume flow is 170 cubic metres per hour; its connection spigot is Ø118 mm, so it connects to 120 and 125 ducts. This size is suitable for a larger room of approximately 12–20 square metres. If the air has to pass through a duct and an external shutter, the volume flow is lower: the manufacturer's figure is 120 cubic metres per hour at 31 pascals of resistance.
What this version offers over the standard model is that it keeps running on its own for a while after the light is switched off, and if the room is not used for days, it still ventilates it from time to time. The turn-off delay is 6, 10, 15 or 21 minutes, the interval mode 8, 12 or 24 hours, and the start can be delayed by 0, 45, 90 or 120 seconds. All three values are codeable inside the unit, with all electronic functions optionally adjustable at high or low level.
The manufacturer recommends this size for small to medium-sized rooms, in private buildings just as in commercial or industrial buildings: for bathrooms, washrooms, changing rooms, utility rooms and kitchenettes. This unit is not suitable for ventilating large retail premises, workshops or warehouses — they need an industrial fan, and we will gladly help you with that too. The M1 series is developed in Germany by Helios; its front facade is completely closed, a multi-award-winning design, and the air flows in from all sides — so it conceals the dirty fan opening, and the smooth surface can be kept clean with a single wipe.
Data sheet
The official Helios catalogue page contains the technical data of all three sizes and all versions of the MiniVent M1, the performance curves, the dimensional drawings and the wiring diagram numbers. It is useful for electricians, architects and anyone looking for precise data for the installation. The manufacturer's part number (ref. no.) of this version is 06361.
Did you know? If the room has a suspended ceiling and you want to route the ventilation duct above the ceiling, this is not the right choice — that calls for a centrifugal fan with a recessed casing, even if the duct run is short. The M1 is designed to ventilate through the wall, via a short duct, directly outdoors.
Technical data
Comparison of the four Ø120 versions; highlighted: the variant you are viewing.
| M1/120 | M1/120 N/C | M1/120 F | M1/120 P | ||
|---|---|---|---|---|---|
| Ref. no. | 06360 | 06361 | 06364 | 06363 | |
| Version | Standard model with two speed levels | Turn-off delay and interval mode | With humidity control function | With presence detector | |
| Flow rate free blowing | m³/h | 170 / 150 | |||
| Volume flow at 31 Pa resistance | m³/h | 120 | |||
| Maximum pressure | Pa | 53 | |||
| Power consumption | W | 13 / 10 | |||
| Rated current | A | 0.09 / 0.08 | |||
| Sound pressure level at 3 m | dB(A) | 36 / 32 | |||
| Speed | 1/min | 2350 / 2050 | |||
| Impeller diameter | mm | 111 | |||
| Connection spigot | mm | Ø118 (for 120 and 125 ducts) | |||
| Voltage / frequency / phase | V / Hz | 230 / 50 / 1 | |||
| Turn-off delay time, adjustable | min | – | 6, 10, 15, 21 | 6, 12, 18, 24 | 6 |
| Interval mode, adjustable | h | – | 0, 8, 12, 24 | – | – |
| Start-up delay | s | – | 0, 45, 90, 120 | 0 or 45 | – |
| Humidity limit value, adjustable | % | – | – | 60, 70, 80, 90 | – |
| Backdraught shutter | Fitted as standard, removable | ||||
| Electrical supply line NYM-O | mm² | 3 × 1.5 | 4 × 1.5 | 4 × 1.5 | 3 × 1.5 |
| Wiring diagram no. | 915 | 917 | 919 | 918 | |
| Protection category | IPX5, protection class II | ||||
| Max. air flow temperature | °C | +40 | |||
| Weight | kg | 1.05 | |||
Dimensions
All dimensions in millimetres
The facade measures 176 × 176 mm and projects 39 mm from the wall. The connection spigot is Ø118 mm. The unit is installed 116 mm deep into the wall; in case of restricted space conditions the guide wheel can be removed, which reduces the installation depth to 70 mm. The drilling distance of the fastening screws is 141.5 mm, and the required wall opening is 140 mm.
Performance curve
Click the image to enlarge
The curve shows how much air the fan delivers as a function of the back pressure, calculated for an air density of 1.20 kg/m³. With free blowing at high level it delivers 170 cubic metres per hour, at 31 pascals of resistance 120 cubic metres per hour, and its maximum pressure is 53 pascals. The volume flow of the four Ø120 versions is identical — the difference lies in the electronics, not in the fan.
Why do we recommend it?
Turn-off delay and interval mode without a separate switch
The fan is started by the light switch, and the electronics take care of stopping it: it switches off automatically after the set 6, 10, 15 or 21 minutes. If the room is not used for a longer period, the interval mode ventilates it every 8, 12 or 24 hours — this keeps the air dry in a rarely used washroom or a holiday home. No speed switch is needed, and a 4 × 1.5 mm² supply line is used for the electrical connection.
The backdraught shutter is fitted as standard
The connection spigot contains the tight-closing backdraught shutter, which is not standard equipment in every small room fan. When the fan stops, the shutter closes, so no cold air is drawn into the room through the duct. The shutter can be removed if the installation requires it.
Ball-bearing motor, in any mounting position
The ball bearings are designed for 40 000 operating hours, so the unit works in any position, even directly in the ceiling. The motor has thermal overload protection, and the manufacturer describes it as maintenance-free — however, regular cleaning of the impeller is necessary for this fan too; without it, any fan wears out sooner.
Also for wet room zone 1
It is made with jet water protection IPX5 and protection class II, so it can be installed in zone 1 according to DIN VDE 0100-701, i.e. also near the shower and the bathtub. The electrical connection is made easier by screwless terminals and the circumferential cable storage space of the casing.
Accessories for this product
For Ø125 installation, from our online shop
Frequently Asked Questions
At high level, with free blowing, it moves 170 cubic metres of air per hour, which is sufficient for a room of approximately 12–20 square metres — a larger bathroom, a utility room, a changing room or a washroom in a commercial building. In practice, the resistance of the duct run and the external shutter reduces this figure: the manufacturer's figure is 120 cubic metres per hour at 31 pascals of resistance. We will gladly help you with sizing.
Inside the unit, by coding — the qualified electrician sets this during installation. The turn-off delay is 6, 10, 15 or 21 minutes, the interval mode 0, 8, 12 or 24 hours, and the start-up delay 0, 45, 90 or 120 seconds. No separate speed switch is needed, and all electronic functions are optionally adjustable at high or low level. The electrical connection requires a 4 × 1.5 mm² supply line, and the manufacturer's wiring diagram no. is 917.
The volume flow and the spigot size. The 100 delivers 90 cubic metres per hour with a Ø100 spigot, the 120 delivers 170 cubic metres per hour with a Ø118 spigot (for 120 and 125 ducts), and the 150 delivers 260 cubic metres per hour with a Ø145 spigot. The casing also grows: the facade is 147, 176 and 210 mm respectively. For an existing duct diameter, always choose the matching size, because reducing or enlarging creates back pressure, and this costs volume flow.
The ball-bearing motor is designed for 40 000 operating hours, so the unit works in any mounting position — even directly in the ceiling. However, if there is a suspended ceiling and you want to route the ventilation duct above the ceiling, this is not the right choice: that calls for a centrifugal fan with a recessed casing, even if the duct run is short.
No. An axial fan cannot cope with the pressure in the common stack: either it pushes the air back into the room, or it cannot extract it. A common exhaust stack needs a centrifugal fan designed for duct systems. This unit is designed to ventilate through the wall, via a short duct, directly outdoors.
Yes. The unit is made with jet water protection IPX5 and protection class II, so it can also be used in zone 1 according to DIN VDE 0100-701 — i.e. also in the part of the wet room close to the shower. The electrical connection should be carried out by a qualified electrician.