Helios M1 MiniVent small room fan
The Helios M1 MiniVent is the quietest axial small room fan range in our product line-up, in three sizes: size 100 moves 90, size 120 moves 170 and size 150 moves 260 cubic metres of air per hour. The smallest size has a noise level of 25 dB(A) at a distance of 3 metres on the low level, and the largest has a highly efficient EC motor.
Every size runs at two speeds, a backdraught shutter is fitted as standard in its connection spigot, and it has an enclosed front facade that conceals the dirty fan opening. It is available as a standard model and in versions with turn-off delay, a humidity control function and a presence detector. Use the size selector to choose the size that fits your duct. Our expert staff will help you with sizing and choosing accessories.
Helios M1 MiniVent: our quietest and most beautiful axial small room fan, in three sizes
The Helios M1 MiniVent is the premium class among the German manufacturer's axial small room fans, and it is also the quietest range in our own product line-up. All three sizes come with two speed levels, a tight-closing backdraught shutter is fitted as standard in the connection spigot, and each has an enclosed, award-winning front facade: the air flows in from all sides, so the facade conceals the dirty fan opening, and the smooth surface can be kept clean with a single wipe.
The smallest size has a noise level of 25 dB(A) at a distance of 3 metres on the low level — thanks to Helios ultraSilence technology. The largest size, 150, has a highly efficient EC motor: on the low level it moves 220 cubic metres of air per hour on 4.5 watts. We recommend this range wherever every item, from the tiles and sanitaryware to the doors and windows, has been carefully chosen, and the ventilation cannot be the exception.
Choose the size
Click the size that fits your duct
Which size do you need?
First the duct diameter, then the size of the room
The choice is decided primarily by the existing duct diameter: size 100 connects to a Ø100 duct, size 120 to a Ø120 or 125 duct, and size 150 to a Ø150 duct. A reducer or an enlarger creates back pressure and reduces the volume flow.
If the installation is still ahead of you, the size of the room is what counts: size 100 is sufficient for a room of about 6–10, size 120 for 12–20 and size 150 for 20–30 square metres. You can also choose a larger size for a smaller room if you want more intensive extraction — but this comes at the cost of more noise. The manufacturer's flow rates apply to free blowing; if the air has to pass through a duct and an external shutter, the actual value is lower (this is why the table also shows the value measured at 31 pascals resistance). Our expert staff will help you with sizing.
Technical data
Comparison of the three sizes, with the manufacturer's data for the standard models
| M1/100 | M1/120 | M1/150 | ||
|---|---|---|---|---|
| Ref. no. (standard model) | 06171 | 06360 | 06041 | |
| Motor | AC | AC | Highly efficient EC | |
| Flow rate free blowing | m³/h | 90 / 75 | 170 / 150 | 260 / 220 |
| Volume flow at 31 Pa resistance | m³/h | 60 | 120 | 180 |
| Maximum pressure | Pa | 45 | 53 | 33 |
| Power consumption | W | 9 / 5 | 13 / 10 | 8 / 4.5 |
| Sound pressure level at 3 m | dB(A) | 30 / 25 | 36 / 32 | 39 / 35 |
| Speed | 1/min | 2650 / 2250 | 2350 / 2050 | 1900 / 1600 |
| Impeller diameter | mm | 92 | 111 | 137 |
| Connection spigot | mm | Ø98 (for duct size 100) | Ø118 (for duct size 120/125) | Ø145 (for duct size 150) |
| Facade dimensions | mm | 147 × 147 | 176 × 176 | 210 × 210 |
| Installation depth (without guide wheel) | mm | 96 (52) | 116 (70) | 142 (76) |
| Drilling distance | mm | 116 | 141.5 | 170 |
| Weight | kg | 0.80 | 1.05 | 1.20 |
| Recommended room size | m² | approx. 6–10 | approx. 12–20 | approx. 20–30 |
| Voltage / frequency / phase | V / Hz | 230 / 50 / 1 | ||
| Backdraught shutter | Fitted as standard, removable | |||
| Protection category | IPX5, protection class II | |||
| Max. air flow temperature | °C | +40 | ||
All 10 variants of the range
Alongside the standard model there are also variants with turn-off delay, humidity control and a presence detector — click the name to go to the product
| Product | Version | Ref. no. |
|---|---|---|
| Helios M1/100 MiniVent | Standard model with two speed levels | 06171 |
| Helios M1/100 N/C MiniVent | Turn-off delay and interval mode | 06172 |
| Helios M1/100 F MiniVent | Humidity control function | 06175 |
| Helios M1/100 P MiniVent | Presence detector | 06174 |
| Helios M1/120 MiniVent | Standard model with two speed levels | 06360 |
| Helios M1/120 N/C MiniVent | Turn-off delay and interval mode | 06361 |
| Helios M1/120 F MiniVent | Humidity control function | 06364 |
| Helios M1/120 P MiniVent | Presence detector | 06363 |
| Helios M1/150 MiniVent | Standard model with two speed levels, EC motor | 06041 |
| Helios M1/150 F MiniVent | Humidity control function, EC motor | 06043 |
The standard model runs at two speeds, with a two-speed switch. The N/C keeps running for a while after the light is switched off, and automatically ventilates a rarely used room from time to time. The F has a humidity control function, and the P has a presence detector, so it does not even need a light switch. The manufacturer also makes size 150 with turn-off delay (N/C) and as a 0-10 V controllable type; please ask our staff about these.
Performance curves
How much air the fan delivers depending on the back pressure
The curves are based on an air density of 1.20 kg/m³. The longer the duct run and the more bends it contains, the higher the back pressure — this is why this range is designed for a short duct run led out through the wall. The size 150 diagram also shows the levels of the 0-10 V type as dashed lines.
Data sheet
The official Helios catalogue page contains the technical data, performance curves, dimensional drawings and wiring diagram numbers of all three sizes and every variant. It is useful for electricians, architects and anyone looking for precise data for the installation.
Did you know? If the room has a suspended ceiling and you would run the ventilation duct above the ceiling, this is not the right choice — that calls for a centrifugal fan with a recessed casing, even if the duct run is short. The M1 is designed to ventilate through the wall, via a short duct, directly outdoors.
Accessories from our online shop
The size of the external shutter and the duct follows the fan's spigot: size 100 takes Ø100, size 120 takes Ø125 and size 150 takes Ø150 accessories
The standard models also need a two-speed switch for changing speed — the MVB speed switch is the same for all three sizes. The variants with turn-off delay, humidity control and presence detector do not need a speed switch, as their electronics handle the speed levels.
Frequently Asked Questions
It is decided primarily by the existing duct diameter: size 100 connects to a Ø100 duct, size 120 to a Ø120–125 duct and size 150 to a Ø150 duct. A reducer or an enlarger creates back pressure and reduces the volume flow. For a new installation, the size of the room is what counts: size 100 is sufficient for about 6–10, size 120 for 12–20 and size 150 for up to 20–30 square metres. You can also choose a larger size for a smaller room if you want more intensive extraction — but this comes at the cost of more noise.
The standard model has no letter code: it comes with two speeds and works with a two-speed switch. The N/C offers turn-off delay and interval mode, meaning it keeps running for a while after the light is switched off, and automatically ventilates a rarely used room from time to time. The F has a humidity control function: it starts when the humidity rises. The P has a presence detector, meaning it switches on when someone enters the room — so it does not even need a light switch. The table above shows which version is available in which size.
For the standard models, yes: they can be wired for two speeds, and changing speed requires an operating and speed switch 0-1-2 — the Helios MVB switch is made for this, and we carry it too. The N/C, F and P versions do not need a speed switch, because their electronics handle the speed levels and switching on and off.
The motor with long-life ball bearings is designed for 40 000 operating hours, so every size works in any mounting position — even directly in the ceiling. However, if there is a suspended ceiling and you would run the ventilation duct above the ceiling, this is not the right choice: that calls for a centrifugal fan with a recessed casing, even if the duct run is short.
No. An axial fan cannot cope with the pressure in the shared riser: it either pushes the air back into the room or cannot carry it away. A shared riser needs a centrifugal fan designed for ducted systems. The M1 is designed to ventilate through the wall, via a short duct, directly outdoors.
Yes, every size. The units come with jet water protection IPX5 and protection class II, so they can also be used in wet room zone 1 according to DIN VDE 0100-701 — that is, in the part of the wet room close to the shower. The electrical connection should be made by a qualified electrician.